Baxi Assure Combi (25, 30, 36, 25 LPG, 30 LPG, 36 LPG)
Combi, natural gas and LPG
Combustion figures
| Figure | Natural gas (G20) | LPG (G31) |
|---|---|---|
CO₂ at high rate More infoHide infoPrinted as a plus and minus tolerance, e.g. 9.0 + 0.3 – 0.2 means 0.3 above and 0.2 below. From the gas valve setting table (MI 9.3.12 Tab.23 and Setting the gas valve), checked in calibration mode. MI 7.4.2 says the case front panel must be fitted when checking combustion. The commissioning check in MI 7.4.2 gives only CO and CO/CO₂ ratio limits. | 9.0% + 0.3 – 0.2 | 10.5% + 0.5 – 0.1 |
CO₂ at low rate More infoHide infoNG figure is printed 8.5 + 0.1 – 0.4 in Tab.23 and 8.5 + 0.1 — 0.4 (longer dash) in the Setting the gas valve steps; taken as the same figure. | 8.5% + 0.1 – 0.4 | 10.0% + 0.1 – 0.5 |
Maximum CO More infoHide infoFrom the combustion procedure flowchart (MI 7.4.2 Fig.46), with the case front panel fitted. The MI says NG and LPG data are the same unless stated otherwise. |
|
|
CO/CO₂ ratio |
|
|
O₂ | Not given in MI | Not given in MI |
Working inlet pressure More infoHide infoNG: at the meter 19–23 mbar (MI 7.4.1 Fig.42). Checked at maximum rate; the MI also says the inlet test point pressure must be at least 18 mbar. LPG: supply pressure from the gas category table (MI 14.3). Measurement point not stated in MI. The MI gives no LPG version of the NG pressure diagram. |
| 37 mbar |
Gas rate at maximum More infoHide infoMeasured with any other appliances and pilot lights turned off (MI 7.4.1). |
|
|
Flue integrity More infoHide infoAt the air inlet test point, boiler at maximum rate. | O₂ ≥ 20.6% CO₂ < 0.2% | O₂ ≥ 20.6% CO₂ < 0.2% |
From 7750729-01
Enter service mode for high and low rate
High rate
Steps not added yet. Follow the MI.
Low rate
Steps not added yet. Follow the MI.
Ending the test: follow the MI.
Models and GC numbers
| Model | GC number | Gas |
|---|---|---|
| Assure Combi 25 | 47-077-42 | NG |
| Assure Combi 30 | 47-077-43 | NG |
| Assure Combi 36 | 47-077-44 | NG |
| Assure Combi 25 LPG | 47-077-45 | LPG |
| Assure Combi 30 LPG | 47-077-46 | LPG |
| Assure Combi 36 LPG | 47-077-47 | LPG |
Source: Baxi Assure Combi 25 - 30 - 36, 25 LPG - 30 LPG - 36 LPG installation and service manual, 7750729-01.
Sections: 3.1.3 Gas category; 3.2.1 Technical information; 7.4.1 Check the operational (working gas inlet pressure and gas rate); 7.4.2 Checking combustion - chimney sweep mode; 9.1 General; 9.3.12 Gas valve; 14.3 Differences for LPG models.
Spotted something wrong? Tell us.
Check these figures against the MI for the appliance in front of you, matched by GC number and manual date. Combustion work needs a calibrated analyser and a Gas Safe registered engineer.