Baxi Baxi Combi (224, 228, 424, 428)

Combi, natural gas

Combustion figures

FigureNatural gas (G20)
CO₂ at high rate
More infoHide infoFrom Setting the gas valve (MI 10.3.7). Case front panel fitted, boiler run for several minutes in chimney sweep mode at maximum rate, probe in the flue sample point. If CO₂ is reset at one rate, recheck the other.
9% +0.4, −0.2
CO₂ at low rate
More infoHide infoFrom Setting the gas valve (MI 10.3.7), boiler at minimum rate in chimney sweep mode.
8.5% +0.1, −0.4
Maximum CO
More infoHide infoSame limit at maximum and minimum rate (Fig.44 combustion procedure).
<350 ppm
CO/CO₂ ratio
More infoHide infoSame limit at maximum and minimum rate (Fig.44, MI 10.1 and 10.3.7).
<0.004
O₂
Not given in MI
Working inlet pressure
More infoHide infoFrom Fig.40 (MI 7.4.1). At the meter: 19–23 mbar. Permissible pressure drop across system pipework ≤ 1 mbar. MI 7.4.1 text also says the working pressure at the inlet test point on the gas cock (Fig.41), at maximum rate, must be AT LEAST 17 mbar, which is lower than the 18–22 mbar Fig.40 shows at the gas cock. Tab.8 gives a nominal inlet pressure of 20 mbar (G20).
Appliance inlet
18–22 mbar
Gas valve test point
17–21 mbar
Gas rate at maximum
More infoHide infoTab.25 and Tab.8 agree. Measure with all other appliances and pilot lights off. Tab.8 gives a minimum gas rate (Qmin) of 0.52 m³/h for all models.
224, 424
2.61 m³/h
228, 428
3.06 m³/h
Flue integrity
More infoHide infoAt the air inlet test point on the flue adaptor, boiler at maximum rate.
O₂ ≥ 20.6%
CO₂ < 0.2%

From 7661586 - 2 - 12072016

Enter service mode for high and low rate

High rate

Steps not added yet. Follow the MI.

Low rate

Steps not added yet. Follow the MI.
Ending the test: follow the MI.

Models and GC numbers

ModelGC numberGas
Baxi Combi 22447-077-21NG
Baxi Combi 22847-077-22NG
Baxi Combi 42447-077-23NG
Baxi Combi 42847-077-24NG

Source: Baxi Combi 224, 228, 424, 428 Installation and Service Manual, 7661586 - 2 - 12072016.

Sections: 3.2 Technical data (Tab.5, Tab.8); 7.4.1 Check the operational (working gas inlet pressure and gas rate); 7.4.2 Checking combustion - chimney sweep mode; 10.1 General; 10.3.7 Air/gas unit (Setting the gas valve); 14.1 Combustion check on small heating systems.