Baxi Neta-tec Plus Combi GA (24 GA, 28 GA, 33 GA)

Combi, natural gas and LPG

Not in the database yet:
  • This PDF stops at MI p. 31, so MI section 14 Combustion & Calibration (MI p. 42) is missing: check it for CO₂ at high and low rate, maximum CO and O₂ (MI section 14)

Combustion figures

FigureNatural gas (G20)LPG (G31)
CO₂ at high rate
More infoHide infoThe technical data (MI 4.1) gives one CO₂ figure without saying which rate, so it is shown in both rows. Rate not stated in MI. Section 14 Combustion & Calibration (MI p. 42) isn’t in this PDF and may give figures for each rate. The MI says combustion is factory set and checked by the boiler’s Gas Type Check: no combustion measurement is needed at commissioning and the air/gas ratio valve must not be adjusted (MI 10.1).
9.0% ± 0.710.5% ± 1.0
CO₂ at low rate
More infoHide infoSame single technical data figure as the high rate row. Rate not stated in MI.
9.0% ± 0.710.5% ± 1.0
Maximum CO
Not added yet – see MI 14Not added yet – see MI 14
CO/CO₂ ratio
More infoHide infoAt maximum rate, at the flue sampling point (MI 12.1). The MI gives one figure, not split by gas type.
Less than 0.004Less than 0.004
O₂
More infoHide infoSection 14 isn’t in this PDF, so whether the MI gives O₂, and at which rate, isn’t known yet.
Not added yet – see MI 14Not added yet – see MI 14
Working inlet pressure
More infoHide infoAt the inlet gas pressure test point on the gas valve (Fig. 41), boiler at maximum in Chimney Sweep Function (MI 10.2). The MI prints 17mb and 37mb. Technical data (MI 4.1) gives inlet pressure NG 20 mbar, LPG 37 mbar, without saying where it is measured.
Gas valve test point
at least 17 mbar
Gas valve test point
at least 37 mbar
Gas rate at maximum
More infoHide infoAfter 10 minutes (MI 4.1), with all other gas appliances and pilot lights off (MI 10.2).
24
2.54 m³/h
28
2.96 m³/h
33
3.49 m³/h
24
1.92 kg/h
28
2.25 kg/h
33
2.64 kg/h

From © Baxi Heating UK Ltd 2012 (no document number in this PDF)

Enter service mode for high and low rate

High rate

Steps not added yet. Follow the MI.

Low rate

Steps not added yet. Follow the MI.
Ending the test: follow the MI.

Models and GC numbers

ModelGC numberGas
Neta-tec Plus Combi 24 GA47-075-64Not stated
Neta-tec Plus Combi 28 GA47-075-65Not stated
Neta-tec Plus Combi 33 GA47-075-66Not stated

Source: Baxi Neta-tec Plus Combi GA Range Installation & Servicing Instructions, © Baxi Heating UK Ltd 2012 (no document number in this PDF).

Sections: Model Range (p. 2); 4.1 Technical Data; 10.1 Commissioning the Boiler; 10.2 Check the Operational (Working) Gas Inlet Pressure & Gas Rate; 12.1 Performance Safety Check & Annual Servicing.

Spotted something wrong? Tell us.

Check these figures against the MI for the appliance in front of you, matched by GC number and manual date. Combustion work needs a calibrated analyser and a Gas Safe registered engineer.