Glow-worm Checked against MI

Glow-worm Energy7 combi (25c -A, 30c -A, 35c -A)

Combi, natural gas

Combustion figures

FigureNatural gas (G20)
CO₂ at high rate
More infoHide infoCheck programme P.01 set to 100 (100% = Pmax). Wait 5 minutes for a stable reading, then measure at the flue gas analysis point. The MI table heading says the figure applies with the front casing removed or installed.
9.2 ±1%
CO₂ at low rate
Not given in MI
Maximum CO
Not given in MI
CO/CO₂ ratio
Not given in MI
O₂
Not given in MI
Working inlet pressure
More infoHide infoMeasured at the test nipple on the gas stopcock, with the boiler at full load in check programme P.01 and one or more hot taps fully open. Technical data gives a G20 gas supply pressure of 2.0 kPa (20.0 mbar).
Appliance inlet
1.3 to 2.3 kPa (13.0 to 23.0 mbar)
Gas rate at maximum
More infoHide infoMeasured at the gas meter with the front casing on, check programme P.01, after at least 5 minutes, all other gas appliances off. The MI table lists nominal, +5% and −10% figures by Qnw from the data plate; the lines here are the Qnw rows matching each model’s maximum DHW heat input in the technical data (25.7, 30.6 and 35.7 kW). Technical data also gives gas flow at Pmax: DHW 2.7, 3.2 and 3.8 m³/h; heating 1.9, 2.7 and 2.7 m³/h (25c, 30c, 35c).
25c
2.72 m³/h (+5%: 2.86, −10%: 2.45)
30c
3.24 m³/h (+5%: 3.40, −10%: 2.92)
35c
3.78 m³/h (+5%: 3.97, −10%: 3.40)

From 0020300875_01 (09.11.2020)

Enter service mode for high and low rate

High rate

Steps not added yet. Follow the MI.

Low rate

Steps not added yet. Follow the MI.
Ending the test: follow the MI.

Models and GC numbers

ModelGC numberGas
Energy7 25c -A (H-GB)47-019-60NG
Energy7 30c -A (H-GB)47-019-61NG
Energy7 35c -A (H-GB)47-019-62NG

Source: Installation and maintenance instructions Energy7, 0020300875_01 (09.11.2020).

Sections: 3 Technical data; 4 Notes on the documentation; 7.4 / 9.11.1 Checking the gas flow rate; 9.11.2 Checking the gas connection pressure (gas flow pressure); 9.11.4 Checking the CO₂ content; 12.4 Checking the CO₂ content; B Check programmes – Overview.

Spotted something wrong? Tell us.

Check these figures against the MI for the appliance in front of you, matched by GC number and manual date. Combustion work needs a calibrated analyser and a Gas Safe registered engineer.